Signal Conditioners & Isolators

  DC - DC Transmitters

 

Click here to download DC Input pdf
Model Input Output Power
API 4010 G
DC-DC Transmitter, Non-Isolated
DC Voltage or Current
Specify Range
18V Loop Supply
DC Voltage or Current
Specify Range
115 VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC
API 4050 G
DC-DC Transmitter, Non-Isolated
Narrow Input Span
DC Voltage or Current
Specify Range
Narrow Input Span
18V Loop Supply
DC Voltage or Current
Specify Range
115 VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC
API 4300 G
DC-DC Transmitter, Isolated
DC Voltage or Current
Factory Set Range
18V Loop Supply
Fully Isolated
DC Voltage or Current
Specify Range
115 VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC
API 4310 G
DC-DC Transmitter, Isolated
Narrow Input Span
DC Voltage or Current
Specify Range
Narrow Input Range
18V Loop Supply
Fully Isolated
DC Voltage or Current
Specify Range
115 VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC
API 4380 G
DC-DC Transmitter, Isolated
Field Rangeable
4380 G Ranges
4380 G Help
DC Voltage or Current
Field Selectable Ranges
18V Loop Supply
Fully Isolated
C Voltage or Current
Field Selectable Ranges
115 VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC
API 4380 GHV3
Hi Voltage DC-DC Transmitter,
Isolated
Field Rangeable
4380 GHV3 Ranges
DC Voltage or Current
Field Selectable Ranges
High Voltage Input to
200 VDC
18V Loop Supply
Fully Isolated
DC Voltage or Current
Field Selectable Ranges
115 VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC
API 4380 DIN
DC-DC Transmitter, Isolated
Field Rangeable
4380 DIN Help
DC Voltage or Current
Field Selectable Ranges
12V Loop Supply
Fully Isolated
DC Voltage or Current
Field Selectable Ranges
80-265 VAC
48-300 VDC
API 4380 DD
DC-DC Transmitter, Isolated
Field Rangeable

4380 DIN Help
DC Voltage or Current
Field Selectable Ranges
12V Loop Supply
Fully Isolated
DC Voltage or Current
Field Selectable Ranges
9-30 VDC
API 4385 G
DC-DC Transmitter, Isolated
Field Rangeable

4385 G Ranges
DC Voltage or Current
Field Selectable Ranges
True Offset
Non-Interacting Controls
18V Loop Supply
Fully Isolated
DC Voltage or Current
Field Selectable Ranges
115 VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC
DPI HV-DC
Hi Voltage DC-DC Transmitter,
Isolated
Field Rangeable

DPI HV-DC Ranges
High Voltage DC
0-100VDC to 0-1200VDC
Fully Isolated
DC Voltage or Current
Field Selectable Ranges
115 VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC

API 4390
2 Channel DC-DC Transmitter,
Isolated

DC Volts or mA
2 Independent Channels
Fully Isolated
DC Voltage or Current
2 Independent Channels
115 VAC Std.
Opt. 230 VAC
Opt. 9-30 VAC/VDC
API 4391
2 Channel DC-DC Transmitter,
Isolated, Bipolar Output
DC Volts or mA
2 Independent Channels
Fully Isolated
Bipolar 5 Volts or 10 Volts
2 Independent Channels
115 VAC Std.
Opt. 230 VAC
Opt. 9-30 VAC/VDC
API 4392
2 Channel DC-DC Transmitter,
Isolated, Bipolar Input & Output
Bipolar DC Volts or mA
2 Independent Channels
Fully Isolated
Bipolar DC Volts or mA
2 Independent Channels
115 VAC Std.
Opt. 230 VAC
Opt. 9-30 VAC/VDC
API 4393
IsoSplitter

DC-DC Signal Splitter,
Isolated
One DC Voltage or Current Fully Isolated
Two Independent
DC Voltage or
Current Channels
115 VAC Std.
Opt. 230 VAC
Opt. 9-30 VAC/VDC
API 4393 L1
IsoSplitter™

DC-DC Signal Splitter,
Isolated
Sourced Input,
Source or Sink Outputs
One 4-20 mA
18V Loop Power Supply
Fully Isolated
Two Independent
4-20 mA Channels
Source or Sink Outputs
115 VAC Std.
Opt. 230 VAC
Opt. 9-30 VAC/VDC

  Loop-Powered Isolators

 

Click here to download DC Input pdf
Model Input Output Power
API LPI-1
Loop-Powered Isolator
4-20 mA Fully Isolated
4-20 mA
Loop Powered
API LPI-2
Dual Channel
Loop-Powered Isolator
Two 4-20 mA Fully Isolated
Two 4-20 mA
Loop Powered
DPI-2
Dual Channel
Loop-Powered Isolator
Two 4-20 mA Fully Isolated
Two 4-20 mA
Loop Powered

  Loop Power Supplies   

 
Model Input Output Power
API 9046
Power Supplies

115 VAC Std.
Opt. 230 VAC

Isolated
Regulated DC Voltage
Specify 5 to 32 VDC

115 VAC Std.
Opt. 230 VAC

API 9046 CH
Bipolar Power Supplies

115 VAC Std.
Opt. 230 VAC

Isolated
Regulated DC Voltage
Bipolar () Output VDC
Specify 5 to 15 VDC

115 VAC Std.
Opt. 230 VAC

  Thermocouple Input

Click here to download Temperature Input pdf
Model Input Output Power
API 4000 G
T/C or RTD Input Transmitter, Isolated
Field Rangeable
Note: This model discontinued and
replaced by
Camile Bauer VK624
J, K, T, E, R, S Thermocouple
Most  RTDs &
Resistance Elements
Field Selectable Type &  Range

Fully Isolated
DC Voltage or Current
Field Selectable Ranges

115 VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC

API 4100 G
T/C Input Transmitter,
Non-Isolated, Non-Linearized
J, K, T, E Thermocouple
Specify Type & Range

DC Voltage or Current
Field Selectable Ranges

115 VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC

API 4130 GL
T/C Input Transmitter,
Isolated, Linearized
J, K, T, E Thermocouple
Specify Type & Range

Fully Isolated
DC Voltage or Current
Field Selectable Ranges

115 VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC

  RTD Input  

Click here to download Temperature Input pdf
Model Input Output Power
API 4000 G
T/C or RTD Input Transmitter, Isolated
Field Rangeable
Note: This model discontinued and replaced by Camile Bauer VK624
Most  RTDs &
Resistance Elements
J, K, T, E, R, S Thermocouple
Field Selectable Type &  Range
Fully Isolated
DC Voltage or Current
Field Selectable Ranges
115 VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC
API 4001 G
RTD Input Transmitter, Non-Isolated,
Non-Linearized
10 Ω to 2000 Ω RTDs
Specify Type & Range
DC Voltage or Current
Specify Range
115 VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC
API 4001 GL
RTD Input Transmitter, Isolated,
Linearized
10 Ω to 2000 Ω RTDs
Specify Type & Range
Fully Isolated
DC Voltage or Current
Specify Range
115 VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC
API 4001 G SA-B
Differential 2 RTD Input Transmitter,
Non-Isolated,
Non-Linearized
Two 100 Ω 0.00385 RTDs
For Differential Temperature
Factory Set,
Can Be Field Calibrated
DC Voltage or Current
Specify Range
115 VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC

  Frequency Modules

Click here to download Frequency pdf
Model Input Output Power
API 7010 G
Frequency to DC Transmitter, Isolated
10 Hz to 20 KHz
Specify Input Span

Fully Isolated
DC Voltage or Current
Specify Range

115 VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC
API 7500 G
 DC to Frequency Transmitter, Isolated

7500 G Ranges
7500 G Help
DC Voltage or Current
Field Selectable Ranges
18V Loop Supply
Fully Isolated
0-100 Hz to 0-30 KHz
Field Selectable
Specify Open Col. or TTL
115 VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC
API 7500 G SS
DC to Low Frequency Transmitter, Isolated

7500 G SS Ranges
DC Voltage or Current
Field Selectable Ranges
18V Loop Supply
Fully Isolated
0-1 Hz to 0-300 Hz
Field Selectable
Specify Open Col. or TTL
115 VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC
API 7580 G
Frequency to DC Transmitter, Isolated
Field Rangeable

7580 G Ranges
7580 G Help
100 Hz to 30 KHz
Field Selectable Ranges
18V Loop Supply
Fully Isolated
DC Voltage or Current
Field Selectable Ranges
115 VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC

  AC Input

 

Click here to download AC Input pdf
Model Input Output Power
API 6010 G
A C to DC Transmitter, Isolated
AC Voltage or Current
Specify Range
18V Loop Supply
Fully Isolated
DC Voltage or Current
Specify Range
115 VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC
API 6010 G 5A &
API 6010 G 20A
C to DC Transmitters, Isolated
High Current
AC Current (up to 20 A)
Specify Range
Socket & Shunt Included
Fully Isolated
DC Voltage or Current
Specify Range
115 VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC
API 6380 G
A C to DC Transmitter, Isolated
Field Rangeable

6380 G Ranges
6380 G Help
AC Voltage or Current
Field Selectable Ranges
18V Loop Supply

Fully Isolated
DC Voltage or Current
Field Selectable Ranges

115 VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC

API 6380 G S
True RMS A C to DC Transmitter,
Isolated
Field Rangeable

6380 G S Ranges
6380 G S Help
True RMS
AC Voltage or Current
Field Selectable Ranges
18V Loop Supply

Fully Isolated
DC Voltage or Current
Field Selectable Ranges

115 VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC

    Potentiometer Input  

Click here to download Potentiometer Input pdf
Model Input Output Power
API 4003 G
Potentiometer to DC Transmitter,
Non-Isolated
0-100 Ω to
0-1 Mega Ω
Potentiometer
DC Voltage or Current
Specify Range
115 VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC
API 4003 G I
Potentiometer to DC Transmitter,
Isolated
0-100 Ω to
0-1 Mega Ω
Potentiometer
Fully Isolated
DC Voltage or Current
Specify Range
115 VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC
API 4008 G
Potentiometer to DC Transmitter,
Isolated
Field Rangeable
0-100 Ω to
0-1 Mega Ω
Potentiometer
Fully Isolated
DC Voltage or Current
Field Selectable Ranges
115 VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC

  Strain Gauge,
 Bridge, Load Cell Input
 

Click here to download Strain Gauge Input pdf
Model Input Output Power
API 4051 G
Single Strain Gauge to
DC Transmitter,
Non-Isolated
Strain Gauge, Bridge,
Load Cell
Adjustable Excitation
Specify Input Span
DC Voltage or Current
Specify Range
115 VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC
API 4058 G
1-4 Strain Gauge to
DC Transmitter,
Non-Isolated

4058 G Ranges
4058 G Help
1 to 4 Strain Gauges,
Bridges, or Load Cells
Field Selectable Ranges
Adjustable Excitation

DC Voltage or Current
Field Selectable Ranges

115 VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC
API 4059 G
1-4 Strain Gauge to
DC Transmitter, Isolated

4059 G Help
4059 G Ranges
1 to 4 Strain Gauges,
Bridges, or Load Cells
Field Selectable Ranges
Adjustable Excitation

Fully Isolated
DC Voltage or Current
Field Selectable Ranges

115 VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC

API 4059 DIN
1-4 Strain Gauge to
DC Transmitter, Isolated

4059 DIN Ranges

1 to 4 Strain Gauges,
Bridges, or Load Cells
Field Selectable Ranges
Adjustable Excitation

Fully Isolated
DC Voltage or Current
Field Selectable Ranges

115 VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC
API SUM 000
Strain Gauge Summing Board
API SUM 025
Summing Board with API 4059
API SUM 100
Summing Board w. NEMA 4X Box
API SUM 125
Summing Board, API 4059, NEMA 4X Box
Summing Assembly Board
1 to 4 Strain Gauges,
Bridges, or Load Cells
Individually Adjustable
Excitation & Signal Trim
Optional SS Housing

DC Voltage or Current
Use with 4058 G or
4059 G

115 VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC

  Valve Position,
 Math & P-I Converters

Click here to download Valve/Math pdf
Model Input Output Power
API 3200 G
Valve Positioner/Actuator
DC Voltage or Current
Specify Range
100 Ω to 100 kΩ
Feedback Pot
Valve / Actuator
Positioner / Controller
2 SPST Relays
115 VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC
API 4400 G (A+B+C+D) / 4
API 4401 G
(A+B+C) / 3
API 4402 G
(A+B) / 2
API 4403 G
(A+B+CD) / 3
API 4404 G
(A+BCD) / 4
API 4405 G
(ABCD)
API 4406 G
(A+BC) / 2
API 4407 G
(ABC)
API 4408 G
(AB)
Up to 4 DC Voltage or
Current Inputs
Specify Ranges
Addition, Subtraction,
Averaging Versions
Fully Isolated
DC Voltage or Current
Specify Range
115 VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC
API 4440 G
DC to DC Transmitter,
Square Root Extraction
DC Voltage or Current
Specify Range
18V Loop Supply
Square Root Extraction
Full Isolated
DC Voltage or Current
 Square Root of Input
Specify Range
115 VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC

Site Designed and Maintained By Panther Marketing & Design